    Brand Name : Jianqiao
    Model Number : JQTHV-1000
    Certification : CE
    Payment Terms : ,T/T
    Supply Ability : 300/YEAR
    Delivery Time : 5 weeks
    • Product Details
    • Company Profile

    Precision Agree Testing Chamber Customized Optimize Performance

    Premium Agree Chamber for Precision Testing | Optimize Performance


    STANDARD FEATURES
    -Designed to fit over a vibration table.
    -Standard temperature range: -40°C to +150°C
    -Temperature change rates: 5*C/Min.
    -Standard sizes: 27 to 64 cubic feet


    CHAMBER CONSTRUCTION
    -Interiors: are fabricated of heavy gauge brushed finish Type 304 stainless steel.
    -Heliarc welded interior seams to form a rugged, vapor-tight unit.
    -Insulated with non-settling, non-hygroscopic high “R” value fiberglass.
    -Exteriors: are fabricated of structural steel and corrosion resistant steel sheet metal
    -Removable floor with diaphragm, to allow test product to be attached to vibration table
    -Standard 2” diameter customer port.
    -Dual silicone rubber gaskets to seal door to the chamber.
    -Heavy-duty door hinges and a specially designed, adjustable door latch.
    -Tough, industrial quality, textured enamel paint finish.
    -Access panels for easy serviceability.
    -Stainless steel drain with check valve.
    -Pressure equalization system.
    -Standard chamber finish is medium gray.
    -All chambers allow handling with a forklift.


    REFRIGERATION SYSTEM
    -Heavy duty, industrial quality, semi-hermetic compressors.
    -Thermal expansion valves to control cooling, allowing maximum pulldown rates and high load ratings,without sacrificing one for the other.
    -Liquid injection valves to insure sufficient compressor cooling during all chamber temperature conditions.
    -Bypass systems for accurate temperature control while eliminating life-shortening rapid compressor cycling.
    -Bypass time-out feature shuts compressor off, after timing out in a standby condition, reducing energy consumption and eliminating standby operation when profiles do not require cooling.
    -Refrigeration pressure gauges on all systems.
    -System design backed by years of environmental experience and constructed of high quality commercially available components.
    HEATING SYSTEM
    -Electrical resistance heaters are low mass open nichrome elements supported by ceramic insulators, for fast response and minimal residual heating effects.
    -Heaters baffled from test space to prevent direct radiation on test specimens.
    -Controlled by heavy duty, quiet mercury contactors rated for millions of cycles.
    -Standard thermal links or electronic high temperature limiters with redundant heater contactor.


    AIR CIRCULATION SYSTEM
    -High volume, propeller type fan blades.
    -Externally located fan motors with lubricated-for-life bearings.
    -Integral one-piece stainless steel extended fan motor shafts for long life and minimal vibration.
    -Chamber conditioning systems are interlocked to the air circulation system.
    -Designed to minimize chamber temperature gradients and maximize conditioning system performance.


    INSTRUMENTATION
    -Microprocessor based programmer/controller on all chambers.
    -User selectable Fahrenheit or Celsius temperature indication.
    -Humidity setting and indication in units of percent relative humidity, eliminating the need for dry bulb/wet bulb conversion tables .
    -Operator-oriented features for easy operation and programming.
    -Digital indication of program and control parameters.
    -Looping feature to allow repeating complete or partial programs.
    -Guaranteed soak feature to let process variable reach setpoint before going to the next step.

    -Real-time clock.
    -Protection to retain controller parameters and programs in the event of a power failure.
    -Three-mode controller action, featuring proportional band, rate and reset adjustment for optimal control.


    ELECTRICAL
    Components mounted in a fully enclosed electrical cabinet.
    Power connection terminal block and ground lug for easy utility connections.
    All wiring enclosed in wiring ducts or bundled and strapped.
    All wires numbered for easy identification.
    All wiring meeting or exceeding the National Electrical Code.
    Wire color coded per Internation National specifications.


    SAFETY
    Guards on all conditioner fan blades.
    Non-toxic, non-flammable refrigerants.
    Gauges to continuously indicate refrigeration system pressures.
    Pressure relief valves or fusible plugs on all refrigeration systems.
    High pressure switches on all refrigeration systems, to shut compressors off in the event of excessive discharge pressures.
    Thermal links or fixed heat electronic high temperature limiter with redundant heater contactor, to protect chamber from dangerous over-temperature conditions.
    Conditioning/air circulation interlock, to prevent equipment damage in the event of a fan motor electrical failure.
    All electrical circuits are protected by fuses or circuit breakers.
    Refrigeration compressors protected against overload conditions.


    OPTIONAL ACCESSORIES & EQUIPMENT
    Humidity System
    Removable solid floor: for chamber use without vibration table.
    Optional instrumentation systems
    Instrumentation consoles
    Recorders - circular and strip-chart styles
    Product high and low temperature limit alarms
    Digital communications interfaces (EIA-232 / EIA485 )
    Additional chamber portholes
    Viewing windows
    Window wipers
    Interior lights
    Casters
    Gaseous nitrogen purge
    Acoustic insulation package
    Custom paint finishes
    Larger or smaller capacity refrigeration systems
    Air or water-cooled condensers
    Water mizer package to minimize refrigeration system water consumption (where applicable)
    Liquid nitrogen cooling/assist packages
    Optional heating systems to increase or decrease temperature change rates
    Humidity water deionizer filter packages
    Running time meters
    GENERAL NOTES
    1. Test chamber air temperature control tolerance ±2*F.
    2. Standard humidity specifications: 20% to 95% ±5% RH within the dry bulb temperature range of 40°F (4.5°C) to 185°F (85°C) and limited by a dew point temperature of 40°F (4.5°C).
    3. Options available to match customer utility requirements:
    a. Non-standard power configurations
    b. Air or water-cooled condensers for mechanical refrigeration systems.
    4. Options available to enhance test chamber performance:
    a. Refrigeration packages to increase temperature change rates and live load capacities.
    b. Heating packages to increase temperature change rates.
    5. Stated chamber performance may be affected by the addition of certain optional accessories.
    6. It is Jianqiao s policy to constantly improve quality, features, and performance of its products. As a result, Webber Manufacturing reserves the right to change specifications without notice.


    When a standard answer won’t do…
    In over five decades of experience, Jianqiao Company has gained an excellent reputation for designing and fabricating custom environmental test chambers, as well as the Series 580 chambers described here. In those instances where selections from our standard line do not meet your requirements, we are capable of modifying a standard chamber or building a unit to your exact specifications. Please feel free to consult our factory about such individual special needs, without obligation.


    Additional Products Available
    Temperature and Temperature/Humidity Chambers up to 4,000 cubic feet
    Industrial Freezers to -300°F
    Temp-Climber Ovens to +700°F
    Modular/Panel Units
    Temperature/Altitude and Temperature/Altitude/Humidity Chambers
    Thermal Shock Units
    Solar Radiation Chambers
    Explosion-proof Chambers
    Convection Fluid Equipment
    Portable Temperature Conditioning Systems
    Expendable Refrigerant Test Chambers -- Benchtop and Floor Models



    Model

    JQTHV-500

    JQTHV-1000

    JQTHV-1700

    JQTHV-3400

    Inner Size (cm)

    50*75*65

    80*70*90

    100*100*100

    195*315*516

    Volume (L)

    512L

    1000L

    1700L

    3400L

    Weight (KG)

    Subject to the actual weight

    Temperature Range

    -70℃ to +150℃(A:0℃ B:-20℃ C:-40℃ D: -70℃)

    Humidity Range

    10%~98% RH

    Cooling Rate

    Standard 1℃ /Min or Optional specified

    Heating Up Rate

    Standard 3℃ /Min or specified

    Frequency Range

    3~5000 Hz(adjustable)

    Sine Force (kg)

    300kg to 35000kg for chooses or specified.300kg~35t

    Displacement (mm)

    Please see vibration shaker details

    Max.Load (kg)

    Please see vibration shaker details

    Exterior material

    Standard 1.2mm Electrolytic plate Electrostatic spray paint

    Interior material

    SUS 304# Stainless steel plate

    Floor load resistance

    customized

    Languages

    Chinese , English ,Russian

    Controller

    TW DELTA PLC,7 " or 10" color touch screen control

    Configuration interface

    With USB , WLAN, RS232 port , APP function is optional

    Compressor

    French Tecumseh or German Bitzer brand or Bock

    Power supply

    AC380V @50Hz