Modular Penalized Solid Environmental Walk In and Drive In chambers
for stability testing and storage
Walk-in temperature and humidity testing chambers offer highly
precise and reproducible conditions for climatic and temperature
testing in many industries.
COMMON APPLICATIONS INCLUDE:
• ENVIRONMENTAL TESTING
• ELECTRONICS, AUTOMOTIVE, AEROSPACE,
• BUILDING MATERIALS, MILITARY
• EQUIPMENT, MATERIALS IN GENERAL
• RESEARCH
• QUALITY CONTROL
• PRODUCTION FACILITIES
KEY FEATURES
• The most advanced technology in climate control
• Internal aerodynamic optimization to ensure uniformity of
climatic conditions
• Time saving features with easily configurable testing programs
that can run, start and stop automatically
• Highly resistant stainless steel interior for maximumdurability
and easy cleaning
• Able to comply with the most demanding testing standards and
customer specifications
• Nonpolluting construction and cooling system
• Compliant with international standards and requirements EN, IEC,
DIN, ISO, NP and UNE

Standard refrigeration system is air cooled
Services hub installation needs:
-¾” demineralized water supply
-50mm water drain at floor level
-Electrical cabinet installation needs:
-Supply power 380VAC, 50Hz, Standard refrigeration system is air
cooled
Services hub installation needs:
¾” demineralized water supply
50mm water drain at floor level
Electrical cabinet installation needs:
Supply power (-40°C~+150°C):
400VAC, 50Hz, 80A / 3-Phase + Neutral + Ground
Electrical protection: Circuit breaker 3 x 80A + N with 300mA
differential
3-Phase electrical cable
Water cooled:
-Water flow (at 25 ºC):
- up to 5000 litres/hour (for 40 ºC models)
-Intake pressure: 2 to 5 bar
-Water entry and exit pipe: 1” or 28mm
-Differential pressure between entry and exit: ≥ 2,5 bars
-Maximum temperature of water entry: 26 ºC
-Minimum temperature of water entry: 16 ºC
R-ecommended temperature of water entry: 18 ºC
TEMPERATURE SENSORS
• One (1) PT 100 Class A, located in air treatment tunnel
• One (1) PT 100 Class A, movable sensors for flexible placing
inside chamber
HEATING
• By stainless steel electric heaters located in the air treatment
tunnel
COOLING
• Mechanical compressor group Scroll (low noise, high efficiency)
with enforced ventilation and without use of CFC’s. In -60ºC models
water cooled condenser
is used as standard. As an option the system can be cooled by an
air condenser.
THERMAL SECURITY
-Safety thermostats with High / Low temperature configuration, with
automaticstop of all heating systems.
-High / Low temperature alarms programmed in the controller, with
mute function.
-This function won’t stop the chamber and it’s only used to record
the occurrence and to call the attention of the users with an
audible alarm.
HUMIDITY SENSORS
• To measure and control humidity,Jianqiao has different sensor
technologies: Psychometric, Capacitive, or both.
Consult us for technical support on the
appropriate selection.
HUMIDITY / DRYING
• Humidity: Through thermostatic bath with dew point control.
• Drying: Through thermostatic bath with dew point control and
additional dry coil
SECURITY
• Automatic stop function in case of water failure, with indication
on the controller;
High / Low Temperature alarms; Compressor overload and overheating
alarm .
CONSTRUCTION
• Interior: AISI 304 hermetical welded, vapor tight, stainless
steel
• Exterior: SECC steel with epoxy coating finish
• Insulation: Rock Wool
• Interior illumination: Halogen lamp 12V (only available with
optional window)
• Door: Double silicone joints and anti-condensation heating
frames.
Automaticelectric locks with emergency opening from the inside
REFRIGERATION
Air Flow: Forced through 2 blowers installed at the back wall / top
of the chamber.
• Air Renovation: By lateral port, also for compensating pressure.
• Water Cooled or -20, -40 Air Cooled as option
CUT-OFF PANEL, SECURITY AND COMMUNICATIONS
Mounted on left lateral panel of the chamber and equipped with:
• High / Low safety thermostat
• Main Power switch
• Audible alarms
INCLUSIONS
• RJ45 Ethernet port
• 1 lateral left panel entry port with Ø 100 mm
• 6 casters for leveling and safely parking
• Instructions manual in English (other languages upon request)
• 1 years warranty
HMI controller
Programmable PLC exclusively developed for ARALAB chambers
Easy to use coloured Touch-Screen Display Interface
Resolution of 0,1ºC for Temperature and 0,1% for Relative Humidity
High performance temperature and humidity control with value
correction in all ranges
Capability for creating 50 programs of 50 segments each
Internal non volatile memory for storing test data
Automatic restart of tests due to power failure, without losing
data and restarting test where it was interrupted
Real-time monitoring of all functions and control of equipment.
Manage control settings via MODBUS/TCP
Possibility of programming a delay of the beginning of test
Monitoring and recording of all alarms
Possibility of performing events by external commands
Several outputs for connecting computers or other devices
Alarms management
Graphic representation of the tests and conditions
Remote access through VNC server
Possibility of running computer test programs and export them to
the controller